Project Case Study: 1000 LPH Pharmaceutical Purified Water System with 150 LPH WFI Generation

Introduction

Reliable pharmaceutical water treatment is essential for maintaining consistent water quality throughout manufacturing operations. From purified water generation to Water for Injection (WFI) production, each system must be designed around the facility's process requirements.

CHONGYANG WATER supplied an integrated pharmaceutical water treatment solution featuring a 1000 LPH purified water system, a 150 LPH WFI system, a raw water storage tank, purified water storage and distribution equipment, and approximately 200 meters of distribution piping.

This project demonstrates how multiple pharmaceutical water utilities can be incorporated into a coordinated engineering solution.

1000 LPH pharmaceutical purified water and 150 LPH WFI system installation with stainless steel storage tanks and process piping

1. Project Overview

The project combines two water generation capacities to support different pharmaceutical production requirements.

System Component Project Specification
Purified Water Generation 1000 LPH (1 m³/h)
WFI Generation 150 LPH
PW Purification Technology Double-Pass Reverse Osmosis
Raw Water Storage Raw Water Tank
PW Storage Storage Tank and Distribution System
Distribution Piping Approximately 200 Meters
System Control Electrical Control Panels and Instrumentation

The equipment arrangement integrates water generation, storage, and distribution within the pharmaceutical production facility.

2. Double-Pass RO Purified Water Generation

The 1000 LPH pharmaceutical purified water system incorporates double-pass reverse osmosis technology to reduce dissolved salts and other contaminants in the incoming water.

Double-pass RO provides two consecutive membrane separation stages, supporting improved permeate quality compared with a conventional single-pass arrangement.

The system includes raw water storage, RO membrane equipment, pumps, instrumentation, and electrical control components.

For pharmaceutical applications, appropriate pretreatment, monitoring, sanitization, and qualification are essential to maintaining consistent purified water quality.

Project Water Treatment Process Overview

Raw Water
Tank
➜
RO Feed
System
➜
First-Pass
RO
➜
Second-Pass
RO
➜
PW Storage
Tank
➜
PW Distribution
System

Simplified overview of the confirmed main PW system stages. Detailed pretreatment and WFI generation processes are subject to project documentation.

Learn more about our Pharmaceutical Purified Water Systems and customized double-pass RO water treatment solutions.

3. Purified Water Storage and 200-Meter Distribution Pipeline

Purified water generation is only one part of a pharmaceutical water system. Storage and distribution are equally important because water quality must be maintained until it reaches the manufacturing process.

This project includes a purified water storage and distribution arrangement connected to approximately 200 meters of piping.

Key engineering considerations include:

  • Hygienic piping and suitable product-contact materials
  • Controlled water circulation and distribution
  • Appropriate pipe sizing and hydraulic performance
  • Drainability and minimization of stagnant sections
  • Suitable cleaning, sanitization, and maintenance access

The final distribution design should be evaluated according to the number of points of use, flow requirements, and pharmaceutical water quality specifications.

Explore our Pharmaceutical Purified Water Storage and Distribution Systems for hygienic tanks, circulation loops, and customized water distribution solutions.

Compact pharmaceutical purified water system with double-pass RO membrane equipment, electrical control cabinet and stainless steel storage tank

4. Integrated 150 LPH Water for Injection System

In addition to the purified water generation equipment, the project incorporates a separate 150 LPH Water for Injection system.

WFI is used in pharmaceutical manufacturing processes requiring stringent control of chemical impurities, microbial contamination, and bacterial endotoxins.

The WFI generation unit complements the larger purified water system by providing a dedicated water utility for applications where WFI quality is specified.

The WFI production technology and applicable pharmacopoeial requirements must be confirmed through the project's technical documentation and qualification program.

Pharmaceutical double-pass RO purified water system showing stainless steel membrane housings, control panel and process instrumentation

5. Engineering Integration and System Control

A key feature of this project is the integration of multiple water treatment and distribution components within one facility.

The equipment photographs show stainless steel vessels, RO membrane housings, electrical control cabinets, process piping, and instrumentation.

Coordinated engineering helps improve equipment accessibility, operation, monitoring, and maintenance.

For pharmaceutical facilities, system commissioning should also be supported by appropriate documentation and qualification activities, including DQ, IQ, OQ and PQ , according to project requirements.

Related Pharmaceutical Water Solutions

Explore additional pharmaceutical water treatment technologies and engineering resources:

Conclusion

This project demonstrates CHONGYANG WATER's capabilities in supplying integrated pharmaceutical purified water and WFI generation equipment.

Combining a 1000 LPH double-pass RO purified water system, a 150 LPH WFI unit, raw water storage, and approximately 200 meters of distribution piping provides a coordinated solution for pharmaceutical manufacturing utilities.

Looking for a Pharmaceutical Water Treatment System?

CHONGYANG WATER provides customized PW, WFI, RO, and pharmaceutical water storage and distribution systems.

Whether your project requires a compact pharmaceutical water purification skid or an integrated water generation and distribution solution, our engineering team can assist with equipment selection and system design.

Contact Us & Request a Technical Proposal →